Being Line
Being Line
BIO-RWP CO2 incubator

BIO-RWP CO2 incubator

series water jacket CO2 incubator touch screen

Intelligent touch screen controller

Replace traditional button operation to touch screen interface.

It can display on time performance curve. You can check the temp., humidity (option) and CO2 concentration three group curves changes at the same time. And abnormal alarm and door open or close message.

When parameters are set, the controller will lock the screen automatically, it avoid unauthorized person wrong operation on the machine.

72 hours machine performance inquiry, it is convenient for user to check abnormal situation and track historical running information.

RS-485 communication port as options can be remote control on computer for monitoring the running and start or close the machine.

CO2 concentration sensor

You may need to open door frequently during experiment, infrared sensor is the best choice under this circumstances. Our infrared sensor is very sensitive to CO2 concentration varies and it will be not affected by inside of incubator chamber conditions, measured accurately. It doesn’t like traditional thermal probe that will be sensitive to chamber temp., and humidity that lead to incorrect CO2 concentration data.

If open the door for 30s and close the door, within 3 min the CO2 concentration can resume to the set value 5%.Even if there are many people use the same machine and frequently open and close door, the inside chamber can still maintain CO2 concentration stable and uniform.

Temperature control and monitoring system

A. Incubator temperature control system

PT100 temp. sensor keeps inside chamber temperature accurate. It canadjust the heating power according to the temp. differences between actual temp. in the chamber and set temp. to make sure temp. in the chamber is accurate. It can resume experiment temp. in 3 min after user open and close door to take samples.

B.Water jacket heating system

Water jacket heating method to ensure working chamber temperature is uniform, when it is power off, the chamber can maintain the temp. for a long time.

C.Door heating system

Outer door ring has heating function. The temperature of door ring will be a little bit higher than temp. in the chamber to prevent condensed water coming from the inner glass door. It facilitates observe the experiment process, also it avoid the biological pollution possibility due to the condensed water from the inner glass door.

D.Over temp. protection system

It is an independent backup temp. control system besides the CO2 incubator temp. control system. When the incubator temp. control system failed and caused temp. lose control, the chamber temp. reaches to the over temp. limiter set value, over temp. protection system will cut down the heating and alarm audible with light.

Documentation and failure diagnostic display (Option)

All data can be stored through RS485 port, if any failures, user can read the diagnostic message and data from computer at any time.

Pollution proof control

A. Ultraviolet sterilization

The ultraviolet lamp is placed at the back top of the chamber. It can sterilize the chamber regularly. It kills chamber recycle air bacteria and float bacteria from water tray or slop water in the bottom, effectively prevent pollution during cell culture period.

B.HEPA efficient filters

The CO2 gas quality is a important factor to judge cell culture in the CO2 incubator. HEPA high efficient filters can filter bacteria and dust in the air. It eliminates cross contamination from outer air to incubator chamber air and keep the chamber inside aseptic. Close the door for 5 min, inside air can fast resume to hundred grade clean. HEPA air filter is easy to disassemble without any special instruments.

C.Micro biological HEPA filter

CO2 access port equips micro biological HEPA filter, it can filters diameter ≥0.3um Particles like CO2 gas bacteria and dust, the efficient reaches to 99.99%.

Cycle fan speed adjustable automatically

Cycle fan speed can be adjusted automatically. When chamber temp. is stable, the fan speed will be lower down, the speed will be adjusted to a suitable speed that the cell can growth. It avoids the fast fan speed that evaporating the samples.

CO2 inlet control system

We supply pressure release valve together with the equipment. It can control the pressure stable.

The system has pressure protection function, it prevents over pressure or low pressure to the pipes.

Safe Functions

High and low temp. and over temp. alarm          Chamber sensor failure alarm

Door temp. sensor failure alarm                          Over temp sensor failure alarm

CO2 condensation too high or too low alarm    Independent temp. limiter alarm

Door open too long alarm                                  Disinfection and sterilization status reminder


Specifications

Technical parameter

ModelBIO-170RWPBIO-240RWP
Electrical requirementAC220V/50Hz
Input power700W1000W
Heating powerWater jacke
Temp. control rangeRT+5 - 50℃
Work environment temp+5 - 30℃
Temp. accuracy±0.1℃
CO2 control range0 - 20%
CO2 control accuracy±0.1% (IR sensor)
CO2 restore time(Door open 30s, recovery to 5%) ≤3min
Temp. restore time(Door open 30s, recovery to 37℃ ) ≤ 8min
Related humidityNature vaporate > 95% (Can equip with related humidity digital display)
Volume170L240L
Chamber size W×D×H(mm)530×460×720600×520×780
Overall size W×D×H(mm)684×700×960754×760×1020
Standard shelves qty3 pcs
SterilizationUV sterilization+HEPA sterilization

Note: All parameters are measured at 25℃